We manufacture two types of combined reference electrodes based on our RB15 Manganese Dioxide and LD15 Silver/Silver Chloride Reference Electrodes. Please note that the LD15 unit is not suitable for seawater immersion or the tidal splash zone where we recommend using the RB15 manganese dioxide reference electrode.
This unique reference electrode combines a MMO coated titanium tubular anode which houses the RB15 or LD15 reference electrode.The MMO unit can be used as a pseudo reference electrode or to measure current flow.
Data sheets and installation procedures for the RB15 and LD15 reference electrodes are applicable for these combined electrodes and can be found in the panel on the right hand side of this page.
A combination reference electrode for corrosion monitoring; a silver/silver chloride reference electrodes with mixed metal oxide (MMO) coated titanium outer tube.
Some specifications require the use of combination reference electrodes for corrosion monitoring. These are usually reference electrodes with mixed metal oxide (MMO) coated titanium outer tube.
The MMO titanium tube is effectively a back up pseudo reference electrode in the unlikely event that the main electrode fails but can also be used for current measurement.
RB15 manganese dioxide and mixed metal oxide (MMO) coated titanium
+175mV (+/- 20mV) wrt saturated calomel electrode for the RB15 reference electrode
+/- 3mV over a 24 hour period
+/- 10mV over 20 years
50 years for the RB15 manganese dioxide reference electrode
100 years for the MMO Titanium
Nylatron
Cementitious >250mm2
Approx. 20mm x 110mm
Twin core 0.75mm2 PVC/PVC white outer with blued for the manganese dioxide reference electrode and yellow for the MMO tintanium tube.
Calibrated under laboratory conditions.
Unique identification numbers.
Calibration certificates for each contract.
Some specifications require the use of combination reference electrodes for corrosion monitoring. These are usually reference electrodes with a mixed metal oxide (MMO) coated titanium outer tube.
The MMO titanium tube is effectively a back up pseudo reference electrode in the unlikely event that the main electrode fails and can also be used for current measurement and can also be used for current measurement.
LD15 silver/silver chloride and mixed metal oxide (MMO) coated titanium
-15mV (+/- 10mV) wrt saturated calomel electrode for the LD15 reference electrode
+/- 3mV over a 24 hour period
+/- 10mV over 20 years
30 years for the LD15 reference electrode
100 years for the MMO Titanium
99.99% purity
Nylon
Cementitious >175mm2
Approx . 20mm x 100mm
Twin core 0.75mm2 PVC/PVC white outer with blue for the LD15 reference elctrode and yellow for the MMO titanium tube
Calibrated under laboratory conditions.
Unique identification numbers.
Calibration certificates for each contract.