Car park ceiling with electrode sensors installed

Datasheet

RB15/MMO Datasheet

Datasheet for the Castle Electrodes Combined Potential Current Measurement Reference Electrode.


A combination reference electrode for corrosion monitoring; a manganese dioxide reference electrode with mixed metal oxide (MMO) coated titanium outer tube.

Some specifications require the use of combination reference electrodes for corrosion monitoring. These are usually reference electrodes with mixed metal oxide (MMO) coated titanium outer tube.

The MMO titanium tube is effectively a back-up pseudo reference electrode in the unlikely event that the main electrode fails but can also be used for current measurement.

Specifications

Reference electrode type:

RB15 manganese dioxide and mixed metal oxide (MMO) coated titanium

Potential:

+175mV (+/- 20mV) wrt saturated calomel electrode for the RB15 reference electrode

Stability:

+/- 3mV over a 24 hour period

+/- 10mV over 20 years

Design Life:

50 years for the RB15 reference electrode

100 years for the MMO Titanium

Housing type:

Blue Nylatron for the RB15 unit

Junction Type:

Cementitious  >250mm3 dimensional

Dimensions:

Approx. 20mm x 110mm

Cable type:

Twin core 0.75mm2 PVC/PVC white outer with blue for the manganese dioxide reference electrode and yellow for the MMO titanium tube

Quality control:

Calibrated under laboratory conditions.

Unique identification numbers.

Calibration certificates for each contract.

 