Element Type:
Silver/silver chloride Typical 1.2g silver per electrode
Potential:
In seawater the cells assume a potential which is dependent on the chloride ion concentration.
Drift:
less 3mV in 24 hours.
Dimensions:
85 mm long x 15mm diameter
Housing:
White nylon barrel and inserts with IP68 cable gland
Cable:
Expected life:
More than 30 years at a leakage current of 1µA will result in the loss of 0.7 grams of silver. The functional life of the electrode will most likely to be determined by the life of the associated cables.